Planning and Executing FCC Proof-ofPerformance Tests Revised Questions and Answers / Sure, Exams of Manufacturing Technologies

The proper calibration of test equipment is necessary to ensure accurate measurements. Calibration must be performed using test equipment and signals whose accuracy is validated and traceable to what agency? - ✔✔The National Institute of Standards and Technology

Typology: Exams

2024/2025

Available from 07/13/2025

dennis-gathiru-1
dennis-gathiru-1 🇺🇸

115 documents

1 / 1

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
Planning and Executing FCC Proof-of-
Performance Tests Revised Questions
and Answers / Sure A +
The proper calibration of test equipment is necessary to ensure accurate measurements. Calibration
must be performed using test equipment and signals whose accuracy is validated and traceable to
what agency? - ✔✔The National Institute of Standards and Technology (NIST).
Specific test equipment is necessary to complete proof-of-performance (POP) tests in the headend.
Which piece of test equipment is used for headend POP measurements? - ✔✔A waveform monitor.
How is test equipment calibration performed? - ✔✔By the manufacturer or approved service center.
Why is the use of spreadsheets to detail proof-of-performance test procedures recommended? -
✔✔Because of the calculations required.
What must occur in a video signal in order to observe the composite triple beat (CBT) on a spectrum
analyzer? - ✔✔The signal must be turned off.
The number of field test points for proof-of-performance tests depends on: - ✔✔The number of
customers.
Proof-of-performance tests are required if there are _____ or more customers. - ✔✔1000.
Where should at least one proof-of-performance test point be located? - ✔✔At the end of the
longest cascade.
The FCC specifications on how the proof-of-performance tests are to be performed can be found -
✔✔Nowhere - the FCC does not specify test procedures.
What should a bandpass filter be used for during the proof-of-performance signal to coherent beats
test? - ✔✔To eliminate interference generated by the spectrum analyzer itself.

Partial preview of the text

Download Planning and Executing FCC Proof-ofPerformance Tests Revised Questions and Answers / Sure and more Exams Manufacturing Technologies in PDF only on Docsity!

Planning and Executing FCC Proof-of-

Performance Tests Revised Questions

and Answers / Sure A +

The proper calibration of test equipment is necessary to ensure accurate measurements. Calibration must be performed using test equipment and signals whose accuracy is validated and traceable to what agency? - ✔✔The National Institute of Standards and Technology (NIST). Specific test equipment is necessary to complete proof-of-performance (POP) tests in the headend. Which piece of test equipment is used for headend POP measurements? - ✔✔A waveform monitor. How is test equipment calibration performed? - ✔✔By the manufacturer or approved service center. Why is the use of spreadsheets to detail proof-of-performance test procedures recommended? - ✔✔Because of the calculations required. What must occur in a video signal in order to observe the composite triple beat (CBT) on a spectrum analyzer? - ✔✔The signal must be turned off. The number of field test points for proof-of-performance tests depends on: - ✔✔The number of customers. Proof-of-performance tests are required if there are _____ or more customers. - ✔✔1000. Where should at least one proof-of-performance test point be located? - ✔✔At the end of the longest cascade. The FCC specifications on how the proof-of-performance tests are to be performed can be found - ✔✔Nowhere - the FCC does not specify test procedures. What should a bandpass filter be used for during the proof-of-performance signal to coherent beats test? - ✔✔To eliminate interference generated by the spectrum analyzer itself.