F80 Exam Study Guide | 100% Correct
Answers | Verified | Latest 2024 Version
After what date was the F-24 certificate of Fitness not recognized. - ✔✔July 31, 2014
How often must this certificate be renewed? - ✔✔Every 3 years
In what types of buildings and occupancies are coordinators of fire safety and alarm systems in homeless
shelter required? - ✔✔Homeless shelters, one-way voice communication systems, or occupied for more
tha n fifteen persons for a period of more than 30 days.
What is the certificate of occupancy? - ✔✔Determines the number of occupants authorized to be in the
shelter.
Alarm Silence Switch - ✔✔Silences the building's audible and visual devices after evacuation is complete
while the source of the alarm is being investigated.
Building Occupants - ✔✔All persons in the shelter
Carbon Monoxide Detector - ✔✔Device that senses carbon monoxide
Central Station Company - ✔✔Receives alarm signals from a protected premise and retransmits or
otherwise reports such alarm signals to the FDNY
Evacuation - ✔✔Emptying of a building
Emergency Preparedness Plan - ✔✔Provide the information, guidance, direction and assistance needed
to protect the safety of building occupants.
Fire Drill - ✔✔A training exercise
pf3
pf4
pf5
pf8

Partial preview of the text

Download F80 Exam Study Guide | 100% Correct Answers | Verified | Latest 2024 Version and more Exams Constitutional Law in PDF only on Docsity!

F80 Exam Study Guide | 100% Correct

Answers | Verified | Latest 2024 Version

After what date was the F-24 certificate of Fitness not recognized. - ✔✔July 31, 2014 How often must this certificate be renewed? - ✔✔Every 3 years In what types of buildings and occupancies are coordinators of fire safety and alarm systems in homeless shelter required? - ✔✔Homeless shelters, one-way voice communication systems, or occupied for more tha n fifteen persons for a period of more than 30 days. What is the certificate of occupancy? - ✔✔Determines the number of occupants authorized to be in the shelter. Alarm Silence Switch - ✔✔Silences the building's audible and visual devices after evacuation is complete while the source of the alarm is being investigated. Building Occupants - ✔✔All persons in the shelter Carbon Monoxide Detector - ✔✔Device that senses carbon monoxide Central Station Company - ✔✔Receives alarm signals from a protected premise and retransmits or otherwise reports such alarm signals to the FDNY Evacuation - ✔✔Emptying of a building Emergency Preparedness Plan - ✔✔Provide the information, guidance, direction and assistance needed to protect the safety of building occupants. Fire Drill - ✔✔A training exercise

Fire Guard - ✔✔Fire guards report any fire safety violations to the Coordinator of Fire Safety and Alarm Systems in Homeless Shelters. Fire Triangle - ✔✔A fire requires fuel, oxygen, and heat. Free Burning Stage of a Fire - ✔✔Second stage of the three stages of a fire. The fully developed stage of a fire. Incipient Stage of a Fire - ✔✔First stage of the three stages of a fire. The growth stage. In-Building Relocation Area (IBRA) - ✔✔A designated are in a building to which building occupants may be relocated Off-Line - ✔✔Periods of time when CS will, per request of building owner, not transmit fire alarm signals. One-Way Voice Communication - ✔✔Makes announcements from the lobby to building occupants in their apartments/rooms. Out of Service Signage - ✔✔placard (tag) over a defective device (job of impairment coordinator) Partial Evacuation - ✔✔The emptying of a building of some but no all building occupants in response to a fire or an emergency Phase 1 Emergency Elavator Recall - ✔✔Involves using a keyed switch to bring the elevators back to the lobby. Shall - ✔✔Refers to a requirement of the fire code Should - ✔✔Refers to policies, procedures, and practices recommended but not required.

Complete evacuation Why: Lit cigarette left unattended by a tenant ignited a mattress on the fourth floor. How often must a Coordinator of Fire Safety & Alarm Systems in Homeless Shelters be present at the shelter? - ✔✔All times. How often does the building need to be patrolled by the fire guard? - ✔✔Every area of the building shall be patrolled at least once every hour. They must maintain records of their patrols. Where should the emergency preparedness plan be? - ✔✔A copy of the EPP must be maintained on the premises in an approved location and it shall be made available at all times to Fire Department representatives immediately upon request. How often should staff do refresher training sessions designed to familiarize them with their duties pursuant to the plan? - ✔✔1 hour quarterly on each work shift What are the three stages of a fire? - ✔✔1. Incipient stage

  1. Free burning stage
  2. Smolering stage How often should drills be done? - ✔✔Once a month per shift What two things must be done BEFORE conducting a fire drill? - ✔✔1. Call CS and take the fire alarm system off-line
  3. Upon confirmation, a system off-line entry should be made in the log book. What four things need to be documented on the off-line entry during drills? - ✔✔1. Time system was taken off-line
  4. Reason the system was taken off-line
  5. Central Station name and telephone number
  6. Time the system was restored

Who participates in drills? - ✔✔All building occupants, including shelter residents and employees. Who is authorized to report a fire or explosion to the fire department? - ✔✔Any owner, occupant or other person who becomes aware of a fire or explosion or any other emergency should immediately report the emergency to the fire department. The Coordinator of Fire Safety & Alarm Systems in Homeless Shelters must always be knowledgeable about the location on the premises of the following four things: - ✔✔1. Emergency Preparedness Plan for the shelter

  1. Floor plans
  2. Firemen's Service Elevator Keys for the elevator car doors must be kept at the fire commant station for immediate use by the department.
  3. List of building occupants who require assistance during an evacuation. What are some ways an alarm might alert occupants? - ✔✔Loud sirens, bells, speakers, horns, and flashing lights (strobes). Who is responsible for ensuring the inspection, testing, and maintenance for alarms are scheduled? - ✔✔Coordinator of Fire Safety & Alarm Systems Fire Alarm Control Panel (FACP) - ✔✔Monitors inputs and controls output through various types of circuits. What are the three types of signals from the control panel and what do they mean? - ✔✔1. Alarm Signal: A signal initiated by a fire alarm initiating device such as a manual fire alarm pull station, automatic fire detector, water flow switch, or other devices in which activation indicated the presence of a fire. Sends a signal to an FDNY
  4. Supervisory Signal: Indicates that a system or device being monitored has been compromised or is in an abnormal state. This needs to be investigated and corrected.
  5. Trouble Signal: A signal initiated by the fire alarm system ore device that indicates a fault in a monitored circuit or component. This needs to be investigated and corrected. For example, low battery, AC failure, phone line failure, or internal component failure. (Electrical issue in the system) Alarm Silence Switch or Button - ✔✔Silence switch is used to silence the devices after evacuation is complete while investigation is being done.

Double Action Pull Station - ✔✔Require two steps in order to activate the alarm Supervisory Devices - ✔✔Monitor important parts of the system What are the four common supervised conditions for a supervisory alarm? - ✔✔1. Control Valves on sprinkler sstems to ensure they remain open

  1. Pressure supervisory switch controls the pressure level in pressure tanks
  2. Gravity tanks are supervised for high or low water level and high or low temperatures
  3. Electric fire pumps are supervised for pump running, pump failure, and phase reversal What are the two methods used to notify building occupants and employees of a fire emergency at the fire alarm panel? - ✔✔1. General Alarm Method: This method activates all audio/visual devises throughout the bu8ilding when a fire is detected.
  4. Selective Alarm Method: The selective method activates the audio/visual devises only on the floor of alarm as well as the floor immediately above and below. Central Station Transmitter - ✔✔A device that receives alarm signals from protected premises and retransmits those signals to the Fire Department's Bureau of Fire Communication Automatic Sprinkler System - ✔✔Wet system, filled with water Non-automatic Sprinkler System - ✔✔Dry system, no water Standpipe System - ✔✔Provides water that firefighters can manually discharge through hoses onto a fire. Standpipe systems are required in buildings that are over 75 feed in height. HVAC System - ✔✔The supply and movement of air is a primary determinant of the severity of a fire event in a building. It is important that air movement be shut down during a fire. HVAC systems are interfaced to fire alarms so that an alarm signal from the fire alarm witll cause the air handling systems in the area of th alarm to shut down. Smoke Dampers - ✔✔Open and close when required to provide fresh air or to stop smoke passage.

Fire Dampers - ✔✔Close when a rise in temperature occurs Fire Watch - ✔✔a fire watch shall be maintained by one or more persons holding a certificate of fitness as fire guard. Fire guards must be immediately available when the system is out of service except for when the affected area does not exceed 50,000 square feet Portable Fire Extinguishers - ✔✔Portable fire extinguishers weighing 40 lbs or less must be installed so that the top of the extinguisher is not more than 5dr above the floor. If it weighs more than 40lbs it must be installed so that the top of the extinguisher is not more than 3.5 fet above the floor. Class A Fire Extinguisher - ✔✔Combustibles. Wood and paper. Green Triangle. Class B Fire Extingusiher - ✔✔Liquids. Flammable liquic and gas like oil, and gasoline. Square. Class C Fire Extinguisher - ✔✔Equipment Combustible. Electrical equipment. Circle. Class D Fire Extinguisher - ✔✔Metals. Star. Class K Fire Extinguisher - ✔✔Fat/Grease/Oil. Kitchen. K. How often are portable fire extinguisher supposed to be inspected? - ✔✔Monthly Aisle requirement for temporary shelters - ✔✔Aisles shall not be less than 36 inches (3ft) in width, except that cross aisles shall not be less than 48 inces (4ft) in width.