Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
Community
Ask the community for help and clear up your study doubts
Discover the best universities in your country according to Docsity users
Free resources
Download our free guides on studying techniques, anxiety management strategies, and thesis advice from Docsity tutors
COMBO WITH NATE HEAT PUMP EXAM WITH ALL ANSWERS.
Typology: Exams
1 / 27
This page cannot be seen from the preview
Don't miss anything!
Chargingnanheatnpumpnwithnrefrigerantnisnbestnaccomplishedninnthen_______nmode. nA:nHeatingnmode nB:nCoolingnmode nC:nDefrostnmode nD:nEmergencynheatingnmoden-nB:nCoolingnmode Heatnpumpsncannprovidenbothnheatingninnthenwinternandncoolingninnthensummer.nInnwhic hnmodenisnthenheatnpumpnmorenefficient? nA:nHeatingnmode nB:nCoolingnmode nC:nDefrostnmode nD:nEmergencynheatingnmoden-nA:nHeatingnmode Whichnofnthenfollowingncomponentsnisnexclusiventonthenheatnpump? nA:nCondenser nB:nOilnseparator nC:nReversingnvalve nD:nAccumulatorn-nC:nReversingnvalve Whichnofnthenfollowingnairflownratesnisnthenmostnreasonablenfornanheatnpumpnsystemnop eratingninnthenheatingncycle? nA:n 200 ncfmnpernton nB:n 300 ncfmnpernton nC:n 400 ncfmnpernton
nD:n 450 ncfmnperntonn-nD:n 450 ncfmnpernton Duringnthenheatnpump'sncoolingncycle,nthenoutdoorncoilnisnutilizednasnan_________nwhile nthenindoorncoilnisnutilizednasna____________. nA:nCondenser,nevaporator nB:nEvaporator,ncondenser nC:nCompressor,naccumulator nD:nAccumulator,ncondensern-nA:nCondenser,nevaporator Heatnisnpresentninnwinternoutdoornairnuntilnthenoutsidenairnambientntemperaturenreachesn anlowntemperaturenof: nA:n 0 ndegreesnF nB:n 32 ndegreesnF nC:n 273 ndegreesnF nD:n-459ndegreesnFn-nD:n-459ndegreesnF Technicallynthisnisntrue,nbutnnotnpractical.nAnheatnpumpnisndoingngoodntoncontinuentonwor knbelown 10 ndegnF. Thenheatnpumpnutilizes: nA:nTwonfilter-driersnwithnchecknvalves nB:nOnenbi-flownfilter-drier nC:nAnsinglenmono-flownfilter-drierninnthenliquidnline nD:nSomenusenthenbi-flownfilter-driernandnothersnusentwonfilter-driersnwithnchecknvalvesn- nD:nSomenusenthenbi-flow-nfilter-driernandnothersnusentwonfilter-driersnwithnchecknvalves Thencorrectnwayntonsizenanheatnpumpnisntonperformnbothnheatingnandncoolingnloadncalcul ationsnandnselectnthenheatnpumpnsizenby: nA:nAddingnthenheatingnloadnandncoolingnloads nB:nSubtractingnthensmallernloadnfromnthenlargernload nC:nUsingnthenheatingnloadntonsizenthensystem nD:nUsingnthencoolingnloadntonsizenthensystemn- nD:nUsingnthencoolingnloadntonsizenthensystem
nD:nThenpointnatnwhichnthenheatingnandncoolingnloadsnmeetn- nA:nThenlowestntemperaturenatnwhichnthenheatnpumpncannmeetnthenheatingnrequirementn fornthenstructure Whichnofnthenfollowingnisnannincorrectntermnfornthensolenoidnvalventhatnswitchesnthenheat npumpnbetweennthenheatingnandncoolingnmodes? nA:nChangeovernvalve nB:nReversingnvalve nC:nFour-waynvalve nD:nDischargenoperatornvalven-nD:nDischargenoperatornvalve Thenbestnlocationnfornthenoutdoornsectionnofnannairntonairnheatnpumpnis: nA:nWherenitngetsnthenwinternsun nB:nWherenitnisnshelterednfromnthensun'snradiation nC:nWherenitnnevernsnows nD:nUndernthenshelternofnanporchn-nA:nWherenitngetsnthenwinternsun Whatnmaynhappennifnthenbodynofnanreversingnvalvenisnslightlyndented? nA:nNothing,nasntheynarenmadentonbenveryndurable nB:nTheninternalnslidenmaynstick nC:nThenvalvenmaynmakennoisesnfromnthengasntryingntonpassnthroughnpartiallynopennport s nD:nBothnbnandncnarencorrectn-nD:nBothnbnandncnarencorrect Thenreversingnvalvenhasn 4 npipenconnections.nOnenpipenconnectionnisnonnonensidenofnthe nvalvenandnthreenpipenconnectionsnarenonnthenoppositenside.nWhatnisnthencenternconnect ionnonnthensidenwithnthreenpipenconnections? nA:nCompressornsuctionnconnection nB:nCompressorndischargenconnection nC:nOutdoorncoilnconnection nD:nIndoorncoilnconnectionn-nA:nCompressornsuctionnconnection Thenreversingnvalvenhasn 4 npipenconnections.nOnenpipenconnectionnisnonnonensidenofnthe nvalvenandnthreenpipenconnectionsnarenonnthenoppositenside.nWhatnisnthensinglenconnect ionnonnthensidenoppositenthenthreenconnections?
nA:nCompressornsuctionnconnection nB:nCompressorndischargenconnection nC:nOutdoorncoilnconnection nD:nIndoorncoilnconnectionn-nB:nCompressorndischargenconnection Whynarenreversingnvalvesnpilotnoperated? nA:nBecausenpilotnoperatednvalvesnusenthendifferentialnpressurentonoperatenthenvalvenpo rtsninsteadnofnhavingnansolenoidnvalvenworkingnagainstnthenheadnpressure nB:nBecausenthatnisnjustnthenwayntheynarenmade nC:nPilotnoperatednvalvesnarenquiet nD:nHeatnpumpnreversingnvalvesnarenNOTnpilotnoperated!n- nA:nBecausenpilotnoperatednvalvesnusenthendifferentialnpressurentonoperatenthenvalvenpo rtsninsteadnofnhavingnansolenoidnvalvenworkingnagainstnthenheadnpressure Twontechniciansnarenworkingnonnanheatnpumpnsystemnandnarenpreparingntonevacuatenth ensystem.nTechniciannAnsaysnthatninnorderntonpullnangoodnvacuumnthenreversingnvalvenn eedsntonbenswitchednonnandnoffnduringnthenevacuationnsonairnandnmoisturenarennotntrapp edninnthensystem.nTechniciannBnsaysntechniciannAnisnincorrectnandnthatnthenreversingnva lvenwillnnotnswitchnwithnthensystemninnanvacuumnanyway.nWhonisncorrect? nA:nTechniciannAnisncorrect nB:nTechniciannBnisncorrect nC:nBothntechniciansnAnandnBnarencorrect nD:nBothntechniciansnAnandnBnarenincorrectn-nB:nTechniciannBnisncorrect Terminaln"O"nonnanheatnpumpnthermostatnisnusednfor: nA:nOperatingnthenreversingnvalve nB:nOperatingnthenindoornfannmotor nC:nOperatingnthencompressor nD:nOperatingnthencondensernfannmotorn-nA:nOperatingnthenreversingnvalve Terminaln"G"nonnanheatnpumpnthermostatnisnusednfor: nA:nOperatingnthenreversingnvalve nB:nOperatingnthenindoornfannmotor nC:nOperatingnthencompressor nD:nOperatingnthencondensernfannmotorn-nB:nOperatingnthenindoornfannmotor
nA:nAnnaccumulator nB:nEvaporatornpressurenregulator nC:nElectronicnsuctionnthrottlingnvalve nD:nCrankcasenpressurenregulatorn-nA:nAnnaccumulator Compressorncrankcasenheatersnarenusednto: nA:nHelpndecreasenrefrigerantnmigration nB:nReducenthenpotentialnofnliquidnflood-back nC:nReducenthenpotentialnofnfloodednstarts nD:nBothnanandncnarencorrectn-nD:nBothnanandncnarencorrect Anheatnpumpnisnoperatingninnthenheatingnmode.nThenlowernthenoutsidenairntemperature,nt he: nA:nMorenefficientnthenheatnpumpnbecomes nB:nHighernthenSEERnrating nC:nHighernthencompressionnratio nD:nLowernthenbalancenpointn-nC:nHighernthencompressionnratio Whichnofnthenfollowingncannpreventnthenreversingnvalvenfromnchangingnpositions? nA:nLownrefrigerantncharge nB:nOverchargenofnrefrigerant nC:nAirninnthensystem nD:nLownindoornairflownduentonandirtynairnfiltern-nA:nLownrefrigerantncharge Thensupplynairntemperaturenonnannormallynoperatingnheatnpumpnis: nA:nLowernthannthatnofnangasnheatingnsystem nB:nHighernthannthatnofnangasnheatingnsystem nC:nAboutnthensamenasnthatnofnangasnheatingnsystem nD:nHeatnpumpsndonnotnusensupplynairn-nA:nLowernthannthatnofnangasnheatingnsystem
Whennanheatnpumpnisnoperatingninnthencoolingnmode,nthensuctionnlinenatnthencompresso rnshouldnfeeln_____nandnwhennoperatingninnthenheatingnmodenthensamensuctionnlinensho uldnfeeln_____. nA:nCool,nhot nB:nHot,ncool nC:nHot,nhot nD:nCool,ncooln-nD:nCool,ncool HighnSEERnratednheatnpumpsnarenthosenthatnemploy: nA:nScrollncompressorsnandnover-sizedncoils nB:nReciprocatingncompressorsnandnover-sizedncoils nC:nScrollncompressorsnandnaccumulators nD:nReciprocatingncompressorsnandnaccumulatorsn-nA:nScrollncompressorsnandnover- sizedncoils Whichnofnthenfollowingnmeteringndevicesncannimproventhenoperatingnefficiencynofnanheat npump? nA:nThermostaticnexpansionnvalve nB:nAutomaticnexpansionnvalve nC:nFixednorifice nD:nCapillaryntuben-nA:nThermostaticnexpansionnvalve Duringnthendefrostncyclenthenoutdoornfannmotornis: nA:nShutndown nB:nOperatednatnanreducednspeed nC:nSteppednupntonitsnhighestnspeed nD:nAllowedntonrunnatnitsnnormalnspeedn-nA:nShutndown Whichnofnthenfollowingncompressorsnisnmostn"liquidnslug"ntolerable? nA:nReciprocating nB:nScroll
nA:nOne nB:nTwo nC:nThree nD:nFourn-nC:nThree ThenUnitednStatesnDepartmentnofnEnergynhasnmandatednthatnthenminimumnallowablenS EERnratingnfornannewnresidentialnairnconditioningnsystemninstallationnis: nA:n 11 nSEER nB:n 12 nSEER nC:n 13 nSEER nD:n 14 nSEERn-nC:n 13 nSEER Whichnofnthenfollowingnactionsnwillnresultninnandecreaseninnvolumetricnefficiency? nA:nAnnincreaseninnheadnpressure nB:nAndecreaseninnheadnpressure nC:nAnnincreaseninnsuctionnpressure nD:nBothnanandncn-nA:nAnnincreaseninnheadnpressure Thisnisnthenrationofnthenactualndeliveredngasnvolumentonthensweptnvolumenorntotalndisplac ementnofnthencylinder.nThenactualnvolumenofngasninductedninsidenthencylindernforncompr essionnisnlessnthannthentheoreticalncalculatednvolumenbecausenofnthenclearancenvolume .nWhennthengasnisncompressed,nandnisndeliverednbynthendischargenvalve,nnotnallnthengasn isndischargednsincensomenvolumenofnthengasnremainsninsidenthenclearancenvolumenatnhi ghndischargenpressure.nWhennthenpistonnstartsnmovingndownwards,nthensuctionnvalvend oesnnotnopensnimmediatelynbecausenofnthisnhighnpressurengas.nAsnthenpistonnmovesndo wnwardsnthenpressurenofnthengasninnthenclearancenvolumenstartsnreducingnduentonexpan sion.nOnlynwhennthenpressurenofnthisngasnreachesntoncertainnminimumnlevel,nthensuction nvalvenopens.nThusnthenportionnofnthensuctionnstrokenofnthenpistonngoesnunusednandnduri ngnthisncertainnvolumenofnthenrefrigerantnisnnotnsucked.nThisnreducesnthenvolumenofnthenr efrigerantnthatncannbensuckednbynthencylindernornthencompressor. Readnmore:nhttp://www.brighthub.com/engineering/mechanical/articles/51998.aspx? p=2#ixzz14iyB2WTb Anheatnpumpnoperatingninnthencoolingnmodenwouldnbenexpectedntonhavenanreturn-to- supplynairntemperaturendifferentialninnthenrangenof: nA:n 5 nton 6 ndegrees
nB:n 5 nton 8 ndegrees nC:n 8 nton 12 ndegrees nD:n 18 nton 22 ndegreesn-nD:n 18 nton 22 ndegrees Anheatnpumpnoperatingnnormallyninnthenheatingnmodenwouldnbenexpectedntonhavenansup plynairntemperatureninnthenrangenof: nA:n 70 nton 80 ndegrees nB:n 80 nton 90 ndegrees nC:n 85 nton 105 ndegrees nD:n 100 nton 130 ndegreesn-nC:n 85 nton 105 ndegrees Innanyncase,nthencompressor'sndischargenlinentemperaturenshouldnnotnexceednwhatntem perature? nA:n 175 ndegreesnF nB:n 200 ndegreesnF nC:n 225 ndegreesnF nD:n 350 ndegreesnFn-nC:n 225 ndegreesnF Anheatnpumpndefrostsnevennwhenntherenisnnonicenonnthenoutsidencoil.nWhichnofnthenfollo wingnisnmostnlikelynthenproblem? nA:nThendefrostntimenclocknisnsetnforntoonshortnancycle nB:nThenoutdoorncoilnisndirtynandnthensystemnusesnanpressurendifferentialntypenofndefrostni nitiation nC:nThensensingnbulbnofnthendefrostncontrolnisnmountedntoonclosentonthenbottomnofnthenou tdoorncoil nD:nEachnofnthesencouldncausenthenproblemn-nD:nEachnofnthesencouldncausenthenproblem Antechniciannplacesnanheatnpumpnintonthenauxiliarynelectricnheatingnmodenwithnthencomp ressornde- energized.nHenmeasuresnantemperaturenrisenbetweennthenreturnnandnsupplynairnofn 40 nd egrees.nThenmeasurednvoltagenatnthenelectricnelementsnisnexactlyn 222 nvoltsnandnthenme asurednamperagenofnthenheatersnisn 60 namps.nUsingnthenequationnCFMn=nBTUndividednb yn1.08nxnTD,nwhatnisnthenCFMnofnthensystem? nA:n 825 nCFM
Anservicencallnisnmadenonnannair-to- airnheatnpumpnsystemnduringnthenwinternmonths.nThentechniciannarrivesnonnthenjobnandn noticesnthatnthendischargenpressurenisnlownandnthensuctionnpressurenisnhigh.nWhatntwon problemsncouldncausenthisnsymptom:n- nanleakingnreversingnvalvenandnbadncompressornvalves Howncannansystemnbentestedntondeterminenifnthenreversingnvalvensolenoidnisnleakingninte rnally:n- nAntemperaturenmeasurementncannbentakennatntheninletnandnthenoutletnofnthenvalveninnthe nheatingnandncoolingnmode Whatncomponentnmustnalwaysnbende- energizednduringnthendefrostncyclenonnanheatnpump:n-nthenoutdoornfan Whennannair-to- airnheatnpumpnisninnthencoolingnmode,nwhatncanncausenandecreaseninnhigh-sidenandnlow- sidenpressure:n-nanrestrictednindoornmeteringndevice TechniciannAnsaysnthatnthenchecknvalvesninnanheatnpumpnsystemnarenlocatedninnseriesnw ithnbothnmeteringndevices.nTechniciannBnsaysnthatnthenchecknvalvesninnanheatnpumpnsys temnarenlocatedninnparallelnwithnbothnmeteringndevices.nWhichntechniciannisncorrect:n- nBothntechniciansnarencorrect Anservicentechniciannnoticesnthatnanchecknvalvenneedsntonbenreplacedninnanheatnpumpns ystem.nBecausenitnisnanball-typenchecknvalve,nitnisncriticalnfornhimntoninstallnthenvalve:n- nvertically,nwithnthenseatnonnthenbottomnofnthenvalve Afterntroubleshootingnanheatnpumpnsystem,nthentechniciannconcludesnthatnthenchecknval venisndefective.nHenconnectsnanrecoverynsystemnandnremovesnthenrefrigerantnfromnthenu nit.nHenthennproceedsntonunseatnthenoldnchecknvalvenandnremovenitnfromnthensystem.nHe ncleansnthenareanwherenthennewnvalvenwillnbeninstalled,nplacesnitnintonposition,nandnbraz esnitnintonthensystemnwhilennotnprotectingnthenvalve.nAfternanthoroughnevacuation,nhensta rtsnthensystemnandnnoticesnthatnthennewnvalvenisndefective.nWhatncouldnhavenbeennthenp roblemnwithnthennewnvalve:n- nAnheatnsinknwasnnotnusednandnthenvalvenwarped+Thenvalvenmaynhavenbeenndefectivenf romnthenfactory+Thenproblemnwasnmisdiagnosed TechniciannAnsaysnthatnthenauxiliarynheatersnfoundnonnannair-to- airnheatnpumpnarenusedntonincreasenthensystem'snpressurenduringnandefrostncycle.nTech niciannBnsaysnthatnthenauxiliarynheatersnfoundnonnannair-to- airnheatnpumpnarenusedntonincreasensupply- airntemperaturenforncomfortnduringnandefrostncycle.nWhichntechniciannisncorrect:n- ntechniciannB Whennanheatnpumpnswitchesnintonthendefrostncycle,nitnmust:n- nremainninndefrostnuntilnthenoutdoorncoilnhasnreachednanpredeterminedntemperature Andefrostnterminationnthermostatnisncommonlynlocated:n- nonnthenoutdoorncoil,nandnopensnatn55°nF
Temperaturensplitnrefersnto:n- nthentemperaturendifferencenbetweennthenairnenteringnancoilnandnthentemperaturenofnthen coil TechniciannAnsaysnthatnthenoutdoornambientnthermostatncommonlynde- energizesnthencompressornduringnthensecondnstagenofnheatingninnannair-to- airnheatnpump.nTechniciannBnsaysnthatnthenoutdoornambientnthermostatnusednwithnannair -to- airnheatnpumpncommonlynenergizesnthenauxiliarynstripnheatersnduringnthenfirstnstagenofn heating.nWhichntechniciannisncorrect:n-nBothntechniciansnarenincorrect Ifntherenisnmalfunctionninnanhold-backnthermostatnthatnisnusednwithnannair-to- airnheatnpump,nhownwouldnthisnaffectnthensystem:n- nThensystemnwouldnnotnstaynenergizednduringndefrostnifnthenroomnthermostatnisnsatisfied .nThisncouldncausenfreezingnofnthenoutdoorncoil. Antechniciannarrivesnonnanservicencallnfornannair-to- airnheatnpumpnduringnthenheatingnseason.nShennoticesnthatnthensystemnoperatesnnorma llynuntilnthendefrostncircuitnisnenergized.nThensystemnstaysninndefrostnfornapproximatelyn 1 5 nminnwhenntherenisnnonicenornfrostnbuildupnonnthencoil.nWhatncouldnbenthenproblemnwithn thensystem:n-nThendefrostnterminationnswitchnisnstucknclosed Antechniciannreceivesnanservicencallnfornannair-to- airnheatnpump.nThencustomernisncomplainingnaboutninsufficientnheatnduringnlownambient nconditions.nUponnarrivalntonthenjob,nthentechniciannnoticesnthatnthenmechanicalnheatnpu mpnsystemnisnoperatingnproperlynbutnthenauxiliarynheatnisnnotnoperating.nWhatncircuitnsh ouldnbencheckednnext:n-nthensecond-stagenheatingncircuit Antechniciannarrivesnatnanhomenonnanservicencallnfornannair-to- airnheatnpump.nAfternmeasuringnthenairntemperaturenovernthenindoorncoilnandnfindingnant emperaturenrisenofn35°nF,nhendeterminesnthat:n-nthentemperaturenrisenisnsufficient Whatnarensymptomsnofnannair-to- airnheatnpumpnsystemnthatnhasnanlownchargenwhenninnthencoolingnmode:n-nThenlow- sidenpressurenwillndecreasenandnthenindoorncoilnwillnbenpartiallynfrosted Ancustomerncallsnandnsaysnthatnhernair-to- airnheatnpumpnsystemnisnnotncoolingnproperly.nUponnarrival,nantechniciannnoticesnthatnth ensuctionnlinenandncompressornhasnfrostnbuildup.nTechniciannAnsaysnthatnthenproblemnis nprobablynanlowncharge.nTechniciannBnsaysnthatnitnisnpossiblynandirtynairnfilter.nWhichntec hniciannisnmorenlikelyntonbencorrect:n-ntechniciannB Namentwonsymptomsnthatnarencommonntonannover-chargednair-to- airnheatnpumpnsystemnwithnansystemnthatnhasnandirtyncondenser.n- nThendischargenpressurenincreasesnandnthenamperagenincreases Whennannair-to- airnheatnpumpnsystemnhasnannundercharge,nwhatnhappensntonthensuperheatnandnthensu bcoolingnofnthensystem:n-nThensuperheatnincreasesnandnthensubcoolingndecreases
Whennspeakingntonancustomernofnanheatnpumpninstallation,nyounshouldnalsoninformnhimnt hatntonconservenelectricitynhenshould:n-nclosenoffndampersntonroomsnnotnused Innorderntonaddncoolingnefficiency,nanfanndelaynmaynbenusednto:n- nstartnthenindoornmotornafterncompressornstart-up An 12 nXn 8 nreturn-airnductnhasnbeenninstalledntonan3- tonnheatnpumpnsystem.nWhatnwillnbenthenmostnlikelynresultnwhilenoperatingninnthenheatin gnmode:n-nshutdownnonnhigh-pressurencontrol Chargingnanheatnpumpnwithnrefrigerantnisnbestnaccomplishedninnthen_______nmode. nA:nHeatingnmode nB:nCoolingnmode nC:nDefrostnmode nD:nEmergencynheatingnmoden-nB:nCoolingnmode Heatnpumpsncannprovidenbothnheatingninnthenwinternandncoolingninnthensummer.nInnwhic hnmodenisnthenheatnpumpnmorenefficient? nA:nHeatingnmode nB:nCoolingnmode nC:nDefrostnmode nD:nEmergencynheatingnmoden-nA:nHeatingnmode Whichnofnthenfollowingncomponentsnisnexclusiventonthenheatnpump? nA:nCondenser nB:nOilnseparator nC:nReversingnvalve nD:nAccumulatorn-nC:nReversingnvalve Whichnofnthenfollowingnairflownratesnisnthenmostnreasonablenfornanheatnpumpnsystemnop eratingninnthenheatingncycle? nA:n 200 ncfmnpernton nB:n 300 ncfmnpernton nC:n 400 ncfmnpernton
nD:n 450 ncfmnperntonn-nD:n 450 ncfmnpernton Duringnthenheatnpump'sncoolingncycle,nthenoutdoorncoilnisnutilizednasnan_________nwhile nthenindoorncoilnisnutilizednasna____________. nA:nCondenser,nevaporator nB:nEvaporator,ncondenser nC:nCompressor,naccumulator nD:nAccumulator,ncondensern-nA:nCondenser,nevaporator Heatnisnpresentninnwinternoutdoornairnuntilnthenoutsidenairnambientntemperaturenreachesn anlowntemperaturenof: nA:n 0 ndegreesnF nB:n 32 ndegreesnF nC:n 273 ndegreesnF nD:n-459ndegreesnFn-nD:n-459ndegreesnF Technicallynthisnisntrue,nbutnnotnpractical.nAnheatnpumpnisndoingngoodntoncontinuentonwor knbelown 10 ndegnF. Thenheatnpumpnutilizes: nA:nTwonfilter-driersnwithnchecknvalves nB:nOnenbi-flownfilter-drier nC:nAnsinglenmono-flownfilter-drierninnthenliquidnline nD:nSomenusenthenbi-flownfilter-driernandnothersnusentwonfilter-driersnwithnchecknvalvesn- nD:nSomenusenthenbi-flow-nfilter-driernandnothersnusentwonfilter-driersnwithnchecknvalves Thencorrectnwayntonsizenanheatnpumpnisntonperformnbothnheatingnandncoolingnloadncalcul ationsnandnselectnthenheatnpumpnsizenby: nA:nAddingnthenheatingnloadnandncoolingnloads nB:nSubtractingnthensmallernloadnfromnthenlargernload nC:nUsingnthenheatingnloadntonsizenthensystem nD:nUsingnthencoolingnloadntonsizenthensystemn- nD:nUsingnthencoolingnloadntonsizenthensystem
nD:nThenpointnatnwhichnthenheatingnandncoolingnloadsnmeetn- nA:nThenlowestntemperaturenatnwhichnthenheatnpumpncannmeetnthenheatingnrequirementn fornthenstructure Whichnofnthenfollowingnisnannincorrectntermnfornthensolenoidnvalventhatnswitchesnthenheat npumpnbetweennthenheatingnandncoolingnmodes? nA:nChangeovernvalve nB:nReversingnvalve nC:nFour-waynvalve nD:nDischargenoperatornvalven-nD:nDischargenoperatornvalve Thenbestnlocationnfornthenoutdoornsectionnofnannairntonairnheatnpumpnis: nA:nWherenitngetsnthenwinternsun nB:nWherenitnisnshelterednfromnthensun'snradiation nC:nWherenitnnevernsnows nD:nUndernthenshelternofnanporchn-nA:nWherenitngetsnthenwinternsun Whatnmaynhappennifnthenbodynofnanreversingnvalvenisnslightlyndented? nA:nNothing,nasntheynarenmadentonbenveryndurable nB:nTheninternalnslidenmaynstick nC:nThenvalvenmaynmakennoisesnfromnthengasntryingntonpassnthroughnpartiallynopennport s nD:nBothnbnandncnarencorrectn-nD:nBothnbnandncnarencorrect Thenreversingnvalvenhasn 4 npipenconnections.nOnenpipenconnectionnisnonnonensidenofnthe nvalvenandnthreenpipenconnectionsnarenonnthenoppositenside.nWhatnisnthencenternconnect ionnonnthensidenwithnthreenpipenconnections? nA:nCompressornsuctionnconnection nB:nCompressorndischargenconnection nC:nOutdoorncoilnconnection nD:nIndoorncoilnconnectionn-nA:nCompressornsuctionnconnection Thenreversingnvalvenhasn 4 npipenconnections.nOnenpipenconnectionnisnonnonensidenofnthe nvalvenandnthreenpipenconnectionsnarenonnthenoppositenside.nWhatnisnthensinglenconnect ionnonnthensidenoppositenthenthreenconnections?
nA:nCompressornsuctionnconnection nB:nCompressorndischargenconnection nC:nOutdoorncoilnconnection nD:nIndoorncoilnconnectionn-nB:nCompressorndischargenconnection Whynarenreversingnvalvesnpilotnoperated? nA:nBecausenpilotnoperatednvalvesnusenthendifferentialnpressurentonoperatenthenvalvenpo rtsninsteadnofnhavingnansolenoidnvalvenworkingnagainstnthenheadnpressure nB:nBecausenthatnisnjustnthenwayntheynarenmade nC:nPilotnoperatednvalvesnarenquiet nD:nHeatnpumpnreversingnvalvesnarenNOTnpilotnoperated!n- nA:nBecausenpilotnoperatednvalvesnusenthendifferentialnpressurentonoperatenthenvalvenpo rtsninsteadnofnhavingnansolenoidnvalvenworkingnagainstnthenheadnpressure Twontechniciansnarenworkingnonnanheatnpumpnsystemnandnarenpreparingntonevacuatenth ensystem.nTechniciannAnsaysnthatninnorderntonpullnangoodnvacuumnthenreversingnvalvenn eedsntonbenswitchednonnandnoffnduringnthenevacuationnsonairnandnmoisturenarennotntrapp edninnthensystem.nTechniciannBnsaysntechniciannAnisnincorrectnandnthatnthenreversingnva lvenwillnnotnswitchnwithnthensystemninnanvacuumnanyway.nWhonisncorrect? nA:nTechniciannAnisncorrect nB:nTechniciannBnisncorrect nC:nBothntechniciansnAnandnBnarencorrect nD:nBothntechniciansnAnandnBnarenincorrectn-nB:nTechniciannBnisncorrect Terminaln"O"nonnanheatnpumpnthermostatnisnusednfor: nA:nOperatingnthenreversingnvalve nB:nOperatingnthenindoornfannmotor nC:nOperatingnthencompressor nD:nOperatingnthencondensernfannmotorn-nA:nOperatingnthenreversingnvalve Terminaln"G"nonnanheatnpumpnthermostatnisnusednfor: nA:nOperatingnthenreversingnvalve nB:nOperatingnthenindoornfannmotor nC:nOperatingnthencompressor nD:nOperatingnthencondensernfannmotorn-nB:nOperatingnthenindoornfannmotor